HK V6 215 DBV

Flow control valve with secondary pressure relief

HK V6 215 DBV HK V6 215 DBV
HK V6 215 DBV HK V6 215 DBV

Properties

Design
with additional secondary pressure relief valve
pressure-compensated
Material
Housing: Cast iron
Inside parts of steel
Max. operating pressure
250 bar
Einstellbereich
50 - 230 bar

Description

With these 3-way flow control valves, the preferred oil flow (P) is held constant irrespective of the incoming oil flow (IN). The residual oil flow (B) can be diverted to the tank or used for an ancillary consumer
Division: max. 75 % of quantity from IN to P, min. 5 l/min to P

Note

These valves must be set according to the application.

Item

1 Item
Identification Gewinde IN/B Inlet max.
l/min
A
mm
Gewinde P C
mm
D
mm
E
mm
F
mm
Weight
kg
HK V6 215 0323 G 3/4" 70 103 G 1/2" 125 110 52 80 1.840

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.

All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.