HK DHE X 00 AC

Solenoid-operated directional control valve size 6 without coil

HK DHE X 00 AC HK DHE X 00 AC
HK DHE X 00 AC HK DHE X 00 AC

Properties

Design
4/2-way valve or 4/3-way valve
3-chamber valve
with manual emergency operation
for AC coils
Scope of supply
without coil or plug
Max. operating pressure
P, A, B: max. 350 bar / T: max. 160 bar
Volumetric flow
max. 80 l/min (note characteristic curves)
Connection
ISO/Cetop 03 size 6
Mounting
4 pcs. socket head screw M5x30 12.9

Description

Can only be used for AC coils
switching capacity limits see characteristic curves

Note

Valves marked with (P) are leak oil reduced valves. With flow quantities of >70 % of the nominal values here, an increased drop in pressure is to be expected.
Leak oil reduced valves are also used as pilot valves for pilot-controlled solenoid-operated directional control valves.
When using a leak oil-reduced valve type HK DH* 0711 P *** as a pilot valve, the centre position of the main valve is overridden.
The O-rings (NBR 70° Shore A) for the valve port can be ordered as spare part separately under the following article number: 4 pieces OR8.73-1.78

Item

21 Item
Identification Circuit diagram Type Overlap Piston type Version Weight
kg
HK DHE 0610 X 00AC Circuit diagram 4/2 negative (open) 0 [PB/AT]-[ABPT] Spring return 1.350
HK DHE 0611 X 00AC Circuit diagram 4/2 positive (closed) 1 [PB/AT]-[A/B/P/T] Spring return 1.350
HK DHE 0613 X 00AC Circuit diagram 4/2 positive (closed) 3 [PB/AT]-[ABT/P] Spring return 1.350
HK DHE 0614 X 00AC Circuit diagram 4/2 negative (open) 4 [PA/BT]-[A/B/PT] Spring return 1.350
HK DHE 0630 2 X 00AC Circuit diagram 4/2 negative (open) 0/2 [PB/AT]-[PA/BT] Spring return 1.350
HK DHE 0631 2A 00AC Circuit diagram 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] Spring return 1.350
HK DHE 0631 2 X 00AC Circuit diagram 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] Spring return 1.350
HK DHE 0632 2 X 00AC Circuit diagram 4/2 positive (closed) 2/2 [PB/A/T]-[PA/B/T] Spring return 1.350
HK DHE 0710 X 00AC Circuit diagram 4/3 negative (open) 0 [PB/AT]-[ABPT]-[PA/BT] spring return to 0 1.750
HK DHE 0710 9 X 00AC Circuit diagram 4/3 negative (open) 09 [PB/AT]-[ABPT]-[PAB/T] spring return to 0 1.750
HK DHE 0711 X 00AC Circuit diagram 4/3 positive (closed) 1 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0 1.750
HK DHE 0713 X 00AC Circuit diagram 4/3 positive (closed) 3 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0 1.750
HK DHE 0714 X 00AC Circuit diagram 4/3 negative (open) 4 [PA/BT]-[A/B/PT]-[PB/AT] spring return to 0 1.750
HK DHE 0714 9 X 00AC Circuit diagram 4/3 positive (closed) 49 [PA/BT]-[A/B/PT]-[PAB/T] spring return to 0 1.750
HK DHE 0716 X 00AC Circuit diagram 4/3 positive (closed) 6 [PB/AT]-[AT/P/B]-[PA/BT] spring return to 0 1.750
HK DHE 0717 X 00AC Circuit diagram 4/3 positive (closed) 7 [PB/AT]-[A/P/BT]-[PA/BT] spring return to 0 1.750
HK DHE 0718 X 00AC Circuit diagram 4/3 positive (closed) 8 [PB/AT]-[PAB/T]-[PA/BT] spring return to 0 1.750
HK DHE 0719 1 X 00AC Circuit diagram 4/3 positive (closed) 91 [PAB/T]-[A/B/P/T]-[PA/BT] spring return to 0 1.750
HK DHE 0751 2 X 00AC Circuit diagram 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] 2 latching positions 1.750
HK DHE 0711 P X 00AC Circuit diagram 4/3 positive (closed) 1 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0, reduced leak oil 1.750
HK DHE 0713 P X 00AC Circuit diagram 4/3 positive (closed) 3 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0, reduced leak oil 1.750
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Accessories

Coil for HKDH solenoid-operated valve
Electrical plug for solenoid coil DIN 43650 / ISO 4400
Emergency hand operation for directional solenoid valve
Metric screw set, hexagon socket
Cap nut for solenoid-operated directional control valve

Ordering information

Further circuits and versions, volumetric flows and switching power limits on request


Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.

All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.